Seaward Apollo 400 Plus PAT Tester 380A930

Product Code: SEA380A930

Price
£918.00 ex. VAT £1101.60 inc. VAT

In Stock


Add To Favourites
Detailed Description

5th Edition and BS EN50699 Compliant


The Apollo 400+ features a comprehensive range of electrical safety tests with user-configurable test sequences and has storage for up to 2,000 test records. Compatible with our Seaward PATGuard 3 software for record-keeping and reporting.

Key Features:

  • Store up to 2,000 appliance records
  • Download your test results into PATGuard 3 software
  • Handheld & Battery Operated
  • Printer Compatible
  • Point-to-point measurement (Rpe & IR) - needs an optional accessory
  • 25 User-configurable electrical test/visual inspection sequences. Change test limits and add your own custom tests.

FREE PAT testing accessories


The Apollo 400+ Comes Supplied With:

  • 1x test lead and probe with crocodile clip
  • 0.5m IEC lead
  • Mains power lead
  • USB download cable
  • Quick start guide
  • UKAS calibration certificate
  • 30-day free trial of PATGuard 3 software
  • 2 years warranty (subject to terms and conditions, available at www.seaward.co.uk/warranty24)

Why buy the new Apollo+ Series?

  • Large on-board storage
  • High-definition colour display
  • Remote data transfer via hotspot to mobile device from field to office
  • Fixed appliance (point-to-point) testing
  • User configurable tests- for nonelectrical tests and inspections
    e.g. fire extinguishers and PPE

Overview:

This PAT tester is a cost-effective downloadable solution that features a comprehensive range of electrical safety tests to ensure compliance with the 5th Edition Code of Practice and BS EN50699.

With a new processor, testing is now faster and more efficient than ever before, and our new Wi-Fi Hotspot feature means it has never been easier to get results back to your office via your mobile device.

The Apollo 400+ is ideal for mid-volume PAT testing where detailed records are required and even can perform point-to-point tests for quick testing of fixed equipment*.

Streamline the PAT testing process further by using the Apollo 400+ with a compatible wireless label printer, barcode scanner, and PATGuard 3 software.

Electrical Test Functions:

  • Low current earth continuity test (with Zap circuit) guaranteeing accurate measurement
  • Insulation resistance
  • IEC lead test
  • Protective conductor current
  • Touch current
  • Load power/current
  • Alternative leakage current
  • Point-to-point testing of earth continuity and insulation resistance
  • RCD test
  • Power socket test

*Requires optional accessory

Which Seaward Apollo PAT Tester is right for me?

General Features 600+ 500+ 400+
Battery & mains powered
Colour screen & QWERTY keypad
Large internal memory up to 50,00 records and 2,000 photos up to 10,00 records up to 2,000 records
Bluetooth scanner & printer compatible
Password controlled user accounts  
Set up multiple user accounts with varying levels of privileges  
Clone facility to set up multiple testers  
Checkbox supplied as standard  
Test Inspection Features 600+ 500+ 400+
Auto-increment asset ID  
PAT Setup option to allow for custom menus  
Enter asset description after test using keypad or barcode scanner
Comprehensive electrical safety test features
Point to point measurement (Rpe & IR) Optional accessory required
User configurable electrical test/visual inspection sequences 100 100 25
User set sites & locations 100 100  
Risk based retest period calculator  
User definable comments lines against test records 4 5  
Configurable checklists for any workplace test or inspection (user tests)  
On-board camera    
Universal risk assessment    
Health & safety certificates    
Data Transfer 600+ 500+ 400+
1D and 2D Scanner connectivity Reads 1D data only
Read QR code (2D) labels with 2D scanner  
RFID reader connectivity    
Print Pass & Fail labels with 1D barcode
Print Pass & Fail labels with QR code (2D)  
Add your company logo to labels (on large 1D labels only)  
Select from various label formats to print 6 6 6
Download to PC via USB cable
Data Transfer via USB flash drive    
Filter results to be downloaded
Upload previous results to tester for retest  


Accessory bundles:

The Apollo 400+ is compatible with a range of accessories that help to speed up the process of asset recognition, testing, and labeling.  

 

Apollo+ Series Pro Bundle 380A9906

Apollo+ Series Pro Bundle with software 380A9907

Apollo+ Series Elite Bundle 380A9902

Apollo+ Series Elite Bundle with software 380A9903

Test n Tag Printer Pro Pro Elite 2 Elite 2
Test n Tag printer labels
Bluetooth barcode scanner 1D 1D 2D 2D
Apollo kit carry case
PATGuard 3 software 1 year license    

 

PATGuard 3 Software

PATGuard 3 is the ultimate PAT testing software with health and safety reporting. Not only does it offer fast and comprehensive record management, but it also gives you the ability to record any workplace test or inspection, auto-schedule the next tests, and create invoices & reports for clients.

Seaward Apollo 400+ Technical Specification
Earth Continuity (Rpe)
Test Current +/- 200mA DC
Measurement Range 0.05Ω to 19.99Ω
Pass Value User defined
IEC Lead Test
Test Voltage 5VAC nominal
Test Live / Neutral Checks for o/c, s/c and crossed polarity
Touch Current
Test Voltage Supply voltage, maximum load current 16A
Measurement Range 0.10mA to 5mA
Pass Value User defined
Substitute (Alternative) Leakage Current
Test Voltages >25VAC <50VAC
Measurement Range 0.20mA to 19.99mA
Pass Value User defined
Power Socket Test
Voltage Range 207V – 253VAC
Indicates configuration of voltage potential:- Line potential phase to earth
Line potential phase to neutral Line potential neutral to earth
Insulation Resistance (IR)
Test Voltage 500V / 250VDC @ 1mA nominal
Measurement Range 0.10MΩ to 19.99MΩ
Pass Value User defined
Protective Conductor Current/Load
Test Voltage Supply voltage, maximum load current 16A
Measurement Range 0.25mA to 19.99mA
Pass Value User defined
Load Power/Current
Test Voltage 230V +10%, -15%, maximum load current 16A
Test Duration Programmable up to a maximum of 240s
Measurement Range 0.50A to 16.0A
RCD Test
Test Voltage 230V +10%, -15%
Test Current 30mA / 150mA rms sinusoidal
Display Range 0ms to 2000ms
Test Method Internal isolation to avoid tripping distribution board RCD
General
Memory size up to 2,000 records
Weight 1.5kg
Dimensions 230mm x 150mm x 100mm
Power Source Mains or rechargeable battery pack
Supported Printers Test n Tag Pro (339A980)
Test n Tag Elite 2 (339A989)
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE

Recently Viewed