Product Code: METMI3360MED
Available In 3-7 Days
The new series of OmegaPAT XA brings 4 models of the instrument, intended for professional use in the most demanding applications. All of them support user accounts, which means that one device can be used by several electricians. Model versions cover the following fields of testing: portable appliances, welding equipment, medical devices and professional testing of PRCD devices.
All instruments have an advanced built-in user interface that enables the execution of pre-defined and user-created AUTOSEQUENCE®s. Large memory capacity (8 GB microSD card) enables the user long term saving and archiving of data. All the instruments are specially designed for long-term testing, since their memory structure enables simple searching through the archive of devices and quick re-execution of (periodic) tests.
Great emphasis was put on support for peripheral devices such as printers and barcode or QR code scanners and RFID readers (in Bluetooth and wired versions). On top of that, all instrument versions are supported by our Metrel ES Manager PC software.
This instrument comes complete with the manufacturers calibration certificate. Please be aware that these certificates are generic and may also be time lapsed.
If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply. The calibration on this model is subject to various criteria over and above a regular calibration, if you require calibration on this machine then please request a quotation, we will call you with some details.
Metrel MI 3360 Selection Chart | ||||
Measuring function | MI 3360 | MI 3360 25A | MI 3360 M | MI 3360 F |
Visual inspections | • | • | • | • |
Fuse test | • | • | • | • |
Continuity // Protective earth resistance 200mA | • | • | • | • |
Continuity // Protective earth resistance 10A, 25A | • | • | • | |
Insulation Resistance (Riso, Riso-S), | • | • | • | • |
Substitute Leakage Current, Substitute Leakage Current - S | • | • | • | • |
Differential Leakage current | • | • | • | • |
PE leakage current | • | • | • | • |
Touch leakage current | • | • | • | • |
Polarity / Active polarity test | • | • | • | • |
Power (P, S, Q, PF, THDu, THDi, CosØ, I, U) | • | • | • | • |
P-RCD, (2 pole, 3 pole, K/ Di (varistor), S (3-pole)) | • | • | • | • |
PRCD PE probe test, open conductor test, PE conductor test | • | • | • | • |
RCD test, (type A, AC, B, B+, F) | • | • | • | • |
Flash test, (1500V, 3000V) | • | |||
Insulation resistance, IEC/EN 62353 | • | |||
Touch leakage current, IEC/EN 62353 | • | |||
Equipment leakage (direct, differential, alternative) IEC/EN 62353 | • | |||
Applied part leakage (direct, alternative), IEC/EN 62353 | • | |||
Insulation resistance, (optional A 1422) IEC/EN 60974-4 | • | • | • | • |
Welding circuit leakage, (optional A 1422) IEC/EN 60974-4 | • | • | • | • |
Primary leakage, (optional A 1422) IEC/EN 60974-4 | • | • | • | • |
No-load voltage, (optional A 1422) IEC/EN 60974-4 | • | • | • | • |
Clamp current (with optional A 1283) | • | • | • | • |
Metrel MI 3360x Specification | |
Continuity / Protective Earth Resistance | |
Continuity | |
Ranges | 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω |
Resolution | 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω \ |
Accuracy | ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative |
Operating range (acc. to EN 61557-4) | 0.08 Ω … 199.9 Ω |
Test currents | 0.2 A,10 A, 25 A |
Current source (at nominal mains voltage, use of standard accessories) | > 0.2 A at R < 2 Ω |
> 10 A at R < 0.1 Ω at 230 V | |
> 25 A into short circuit at 230 V | |
Open circuit voltage | < 9 V a.c. |
Test Terminals | |
Continuity | |
R (200 mA) | P/S – PE, Socket PE; Socket PE – IEC PE |
R (10 A, 25 A) | P/S – Socket PE; Socket PE – IEC PE |
Protective Earth Resistance | |
R (200 mA) | P/AP – PE, Socket PE |
R (10 A, 25 A) | P/AP – Socket PE |
Insulation Resistance (Riso, Riso-S) | |
Insulation resistance, Insulation resistance –S (250 V, 500 V) | |
Range | 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ |
Resolution | 0.01 MΩ / 0.1 MΩ / 0.1 MΩ |
Accuracy | ±(3 % of reading + 2 D) / ± 5 % of reading /± 10 % of reading |
Output voltage (Um) | |
Range | 0 V … 600 V |
Resolution | 1V |
Accuracy | ±(3 % of reading + 2 D) |
Operating range (acc. to EN 61557-2) | 0.08 MΩ … 199.9 (999) MΩ |
Nominal voltages Un | 250 V, 500 V (- 0 %, + 10 %) |
Short circuit current | max. 2.0 mA |
Test terminals | Riso LN, Socket LN – PE, Socket PE, P/S |
Riso-S LN, Socket LN – P/S | |
Sub-Leakage Current, Substitute Leakage Current - S (Isub, Isub-S) | |
Range | 0.00 mA … 1.99 mA / 2.00 mA … 19.99 mA |
Resolution | 0.01mA / 0.01mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Operating range (acc. to EN 61557-16) | 0.02 mA … 19.99 mA |
Open circuit voltage | 230 V a.c., 110 V a.c. |
Current calculated to mains supply voltage (110 V or 230 V) is displayed. | |
Test Terminals | Isub LN, Socket LN – PE, Socket PE, P/S |
Isub-S LN, Socket LN – P/S | |
Differential leakage current (Idiff) | |
Differential leakage current | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01 mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Influence of load current | < 0.02 mA/A |
Test terminals | Idiff Socket L,N – Socket PE, P/S |
P Socket L – Socket N | |
PE leakage current (Ipe) | |
PE leakage current | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1µA / 0.01mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Test terminals | Ipe Socket L,N – Socket PE |
P Socket L – Socket N | |
Touch leakage current (Ipe) | |
Touch leakage current | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Test terminals | Itou: Socket L,N – P/S |
P: Socket L – Socket N | |
Power | |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power (apparent) (S) | |
Range | 0 VA … 999 VA / 1.00 kVA … 3.70 kVA |
Resolution | 1 VA / 10VA |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power (reactive) (Q) | |
Range | ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr |
Resolution | 1 VAr / 10 VAr |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power factor (PF) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (voltage) (THDU) | |
Range | 0.0 % … 99.9 % |
Resolution | 0.1 % |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (current) (THDI) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Cosinus Φ (Cos Φ) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Current (I) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Voltage (U) | |
Range | 0.0 V … 199.9 V / 200 V … 264 V |
Resolution | 0.1V / 1V |
Accuracy | ±(3 % of reading + 10 D) / ±3 % of reading |
Test terminals | |
P,S,Q,PF,THDU,THDI, Cos Φ, I, U | Socket L – Socket N |
Leaks & Power | |
Power (active) (P) | |
Range | 0 W … 999 W / 1.00 kW … 3.70 kW |
Resolution | 1W / 10W |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Touch leakage current: (Itou) | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01 mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Differential leakage current (Idiff) | |
Range | 0.000 mA … 1.999 mA / 2.00 mA … 19.99 mA |
Resolution | 1 µA / 0.01 mA |
Accuracy | ±(3 % of reading + 3 D) / ±(5 % of reading) |
Operating range (acc. to EN 61557-16) | 0.010 mA … 19.99 mA |
Influence of load current | < 0.02 mA/A |
Power (apparent) (S) | |
Range | 0 VA … 999 VA / 1.00 kVA … 3.70 kVA |
Resolution | 1 VA / 10VA |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power (reactive) (Q) | |
Range | ±(0 VAr … 999) VAr / ±(1.00 kVAr … 3.70) kVAr |
Resolution | 1 VAr / 10 VAr |
Accuracy | ±(5 % of reading + 5 D) / ±5 % of reading |
Power factor (PF) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (voltage) (THDU) | |
Range | 0.0 % … 99.9 % |
Resolution | 0.1 % |
Accuracy | ±(5 % of reading + 5 D) |
Total Harmonic Distortion (current) (THDI) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Cosinus Φ (Cos Φ) | |
Range | 0.00i … 1.00i / 0.00c … 1.00c |
Resolution | 0.01 |
Accuracy | ±(5 % of reading + 5 D) |
Current (I) | |
Range | 0.00 A … 16.00 A |
Resolution | 0.01 A |
Accuracy | ±(3 % of reading + 5 D) |
Voltage (U) | |
Range | 0.0 V … 199.9 V / 200 V … 264 V |
Resolution | 0.1V / 1V |
Accuracy | ±(3 % of reading + 10 D) / ±3 % of reading |
Test terminals | |
P,S,Q,PF,THDU,THDI, Cos Φ, I, U | Socket L – Socket N |
Idiff | Socket L,N – Socket PE, P/S |
Itou | Socket L,N – P/S |
PRCD test | |
Trip-out time (tΔN) | |
Range | 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N) |
Resolution | 1ms / 1ms / 1ms |
Accuracy | ±3ms / ±3ms / ±3ms |
*According to standard AS/NZS 3017 | |
Trip out-current (IΔ) | |
Range | 0.2xI∆N … 2.2xI∆N |
Resolution | 0.05xI∆N |
Accuracy | ±0.1xI∆N |
Test current type | sine-wave (AC), pulsed (A,F), smooth DC (B,B+) |
Test currents (IΔN) | 10 mA, 15 mA, 30 mA;.................100 mA and 300 mA with A1322, A1422 |
Test current size (PRCD standard is AS/NZS 3017) | ±5% |
Test current size (general) | -0/+10% |
Test terminals | tΔN, IΔ Socket – IEC |
RCD Test | |
Trip-out time (tΔN) | |
Range | 0 ms … 300 ms (999 ms*) (½xI∆N) / 0 ms … 300 ms (I∆N) / 0 ms … 40 ms (5xI∆N) |
Resolution | 1ms / 1ms / 1ms |
Accuracy | ±3ms / ±3ms / ±3ms |
*According to standard AS/NZS 3017 | |
Trip out-current (IΔ) | |
Range | 0.2xI∆N … 2.2xI∆N |
Resolution | 0.05xI∆N |
Accuracy | ±0.1xI∆N |
Contact voltage (Uc) | |
Range | 0.0 V … 19.9 V / 20.0 V … 99.9 V |
Resolution | 0.1V / 0.1V |
Accuracy | (-0 % / +15 %) of reading ± 10 D / 0.1 V (-0 % / +15 %) of reading |
Test current type | sine-wave (AC), pulsed (A,F), smooth DC (B,B+) |
Test currents (IΔN) | 10 mA, 15 mA, 30 mA |
Test current size (RCD standard is AS/NZS AS/NZS) | 5% |
Test current size (EN 61008/EN 61009) | -0/+10% |
Test terminals | tΔN, IΔ Mains Socket |
PE conductor (PRCD) | |
PE conductor (Type = 2 pole, 3 pole, S(3 pole)) (R) | |
Range | 0.00 Ω … 19.99 Ω / 20.0 Ω … 99.9 Ω / 100.0 Ω … 199.9 Ω / 200 Ω … 999 Ω |
Resolution | 0.01 Ω / 0.1 Ω / 0.1 Ω / 1 Ω |
Accuracy | ±(2 % of reading + 2 D) / ± 3 % of reading / ± 5 % of reading / indicative |
Operating range (acc. to EN 61557-4) | 0.08 Ω … 199.9 Ω |
Current source (at nominal mains voltage, use of standard accessories) | > 0.2 A at R < 2 Ω |
Open circuit voltage | < 9 V a.c. |
Test terminals | R Socket PE – IEC PE |
PE conductor (Type = K/ Di (varistor)) | |
Test principle: A voltage is applied between PE connections of the PRCD-K. There is a ‘PASS’ if PRCD trips. | |
Open circuit voltage | 24 V |
Output resistance | 220 Ω ± 10 % (IΔN = 30 mA), 620 Ω ± 10 % ((IΔN = 10 mA) |
Test terminals | Result: Socket – IEC |
Open conductor (PRCD) | |
Test principle: Mains voltage is applied to the mains test socket. Disconnection of the L, N and PE connections is performed inside the instrument. There is a ‘PASS’ if the PRCD trips. | |
Test terminals | L open, N open, PE open Socket – IEC |
PRCD PE probe test | |
Test principle: Mains voltage is applied to the mains test socket. A safe voltage sufficiently high to activate the protection circuit in the PRCD is applied to the P/S terminal. | |
Test terminals | Result (manual): Socket, P/S |
Result (auto): Socket – IEC, P/S | |
Polarity | |
Test voltage (normal) | < 50 V |
Test voltage (active) | mains voltage |
Power consumption of tested device during the active test | < 25 VA |
Test terminals | Result (normal, active) Socket – IEC |
Clamp current (I, Idiff, Ipe) | |
True RMS current using 1000:1 current clamp | |
Range | 0.10 mA … 9.99 mA / 10.0 mA … 99.9 mA / 100 mA … 999 mA / 1.00 A … 9.99 A / 10.0 A … 24.9 A |
Resolution | 0.01 mA / 0.1 mA / 1 mA / 0.01 A / 0.1 A |
Accuracy | ±(5 % of reading + 10 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) / ±(5 % of reading + 5 digits) |
Notes | Accuracy of current transformer is not considered. |
Frequency range of current clamp is not considered. | |
Test terminals | I, Idiff, Ipe: CLAMPS terminals |
Insulation resistance Riso (welding equipment) | |
Riso | |
Range | 0.00 MΩ … 19.99 MΩ / 20.0 MΩ … 99.9 MΩ / 100.0 MΩ … 199.9 MΩ |
Resolution | 0.01 MΩ / 0.1 MΩ / 0.1 MΩ |
Accuracy | ±(3 % of reading + 2 D) / ±5 % of reading / ±10 % of reading |
Output voltage (Um) | |
Range | 0 V … 600 V |
Resolution | 1 V |
Accuracy | ±(3 % of reading + 2 D) |
Operating range (acc. to EN 61557-2) | 0.08 MΩ … 199.9 (999) MΩ |
Nominal voltages Un | 500 V (- 0 %, + 10 %) |
Short circuit current | max. 2.0 mA |
Test terminals | |
Riso LN-W: A 1422 | Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – W1 W2 |
Riso W-PE | A 1422: Socket PE (16A-5p, 32A-5p or 16A-3p) – W1 W2 |
Riso LN-PE | A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – Socket PE (16A-5p, 32A-5p or 16A-3p) |
Riso LN (Class II) - P | A 1422: Socket L1 L2 L3 N (16A-5p, 32A-5p or 16A-3p) – MI 3360: P/S |
General Specifications | |
Mains supply | |
Supply voltage, frequency | 110 V / 230 V AC, 50 Hz / 60 Hz |
Supply voltage tolerance | 10 % |
Max. power consumption | 300 VA (without load on test socket) |
Max. load | 10 A continuous, 16 A short duration, 1.5 kW motor |
Mains supply overvoltage category | CAT II / 300V |
Altitude | ≤ 2000 m |
Measuring categories | |
Instrument | Cat II / 300 V |
Test socket | Cat II / 300 V |
Plug test cable | Cat II / 300 V |
Altitude | ≤ 2000 m |
Protection classifications | |
Power supply | Class I, mains supply, Class II, only battery supply |
Pollution degree | 2 |
Degree of protection | IP40 |
IP20 (mains test socket) | |
Case | Shock proof plastic / portable |
Display | Colour TFT display, 4.3 inch, 480 x 272 pixels |
Touch screen | Capacitive |
Communication | |
Memory | depends on microSD card size |
RS232 interfaces | 2 |
USB 2.0 | Standard USB Type B |
Bluetooth | Class 2 |
Dimensions (w×h×d) | 31 cm × 13 cm × 25 cm |
Weight | 6.1 kg |
Reference conditions | |
Reference temperature range | 15 ˚C … 35 ˚C |
Reference humidity range | 35 % … 65 % RH |
Operation Conditions | |
Working temperature range | 0 ˚C … +40 ˚C |
Maximum relative humidity | 85 % RH (0 ˚C … 40 ˚C), non-condensing |
Storage Conditions | |
Temperature range | -10 ˚C … +60 ˚C |
Maximum relative humidity | 90 % RH (-10 ˚C … +40 ˚C) |
80 % RH (40 ˚C … 60 ˚C) | |
Notes | Accuracies apply for 1 year in reference conditions. Temperature coefficient outside these limits is 0.2 % of measured value per ˚C plus 1 digit, otherwise noted. |
Fuses | 2 x T 16 A / 250 V, 32 mm 6.3 mm / 1500 A |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |
Price £369.24 £307.70
Available In 3-7 Days
Price £121.38 £101.15
Available In 3-7 Days
Price £167.94 £139.95
Available In 3-7 Days
Price £1555.14 £1295.95
Available In 3-7 Days