Beha-Amprobe 2100 Gamma 2 Pole Tester

Product Code: AMP2100GAMMA

Price
£82.45 ex. VAT £98.94 inc. VAT

Available In 3-7 Days


Add To Favourites
Detailed Description

Beha-Amprobe 2100-Gamma 2 Pole Tester TUV & GS approved tetser rated CAT III 10000V and CAT IV 600V. Measures up to 1200V DC.

Key Features:

  • Voltage Range 6-1000V AC
  • Voltage Range 6-12000V DC
  • Non-contact voltage detector
  • LCD Display
  • GS38 Compliant
  • Phase Rotation Tester
  • LED Indicator
  • Indication of Polarity

Voltage tester with continuity measurement, phase sequence indication, resistance and NCV

Product Overview:

The Beha-Amprobe 2100-Alpha, 2100-Beta and 2100-Gamma are rugged and reliable two pole voltage testers for voltage and continuity checks. Built tough for use in industrial and commercial environments, the 2100 Series is safety rated up to CAT III 1000 V/ CAT IV 600 V and measures voltage range up to 1000 V AC and 1200 V DC (2100-Gamma only). Designed with reinforced components for dependable performance, the 2100 Series has an ingress protection degree of IP 64 and is built according to voltage tester standard EN 61243-3 and are TÜV and GS approved.

Amprobe 2100-Gamma Anatomy

Key Features:

• Voltage test up to 1000 V, alternating current and 1200 V direct current
• Digital LCD 12…1000 V AC/ 1200 V DC
• Measures resistance up to 1999 Ohm
• Optical and acoustic continuity and voltage test
• Low resistance continuity measurement <10...50 Ohm
• Patented phase rotation indicator, no 3rd hand required
• Single-pole phase test
• Polarity
• Non-contact voltage (NCV/EF) detection

Product information
• Switchable load (load tester) of 300 W at 1000 VAC / 420 W at 1200 VDC via two push buttons, triggering a RCD/FI up to 30 mA
• IP 64, water and dust-resistant
• Integrated probe-tip protection for reducing the danger of injuries

Product highlights
• No unintentional triggering of RCD/FI circuit breakers
• Fast single-handed testing of power sockets with 19 mm contact clearance, without the probe coming away from the unit
• Lighting of measurement points via white LED
• Extremely robust construction with doubly insulated wires

Amprobe 2100-Gamma

Two Button Switchable Load/
RCD Trip Test

Long, durable test leads with wear indicator

Test probe protector cover with accessory storage 

When the two buttons are not pressed
the unit is in high impedance mode,
providing additional safety protection
when testing live power sources,
and avoiding accidental tripping of
residual-current devices (RCD). When
the buttons are pressed the unit is in
low impedance mode, eliminating inaccurate readings as result of ghost voltage. Additionally, in systems with RCDs you can press the buttons to intentionally trip 10 mA or 30 mA RCDs and determine if they are wired correctly.

Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.

Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.

Amprobe 2100 Series Technical Specifications

 

2100-Alpha

2100-Beta 2100-Gamma

Voltage Test

LED Voltage Range

12…690 V AC/DC

12…690 V AC/DC

12…≥690 V AC/DC

LED Indicator

±12, ±24, 50, 120, 230, 400, 690 V

±12, ±24, 50, 120, 230, 400,  ≥690 V

LED Tolerances

acc. To EN 61243-3:2010

LCD Voltage Range

-

12…690 V AC/DC

6…1000 V AC/ 6…1200 V DC

LCD Resolution

-

1 V

LCD Tolerance

-

± (3% rdg + 3 LSD)

LED and LCD Response Time

< 1s

Frequency Range

DC,  16 2/3 Hz…400 Hz

Acoustic Indication

≥ 50 V AC, ≥ 120 V DC

Voltage Detection

Automatic (AC/DC)

Polarity Detection

Full Range

Range Detection

Automatic

Current I

(load buttons not activated)

≤3.5 mA AC/DC at 690 V AC/DC

≤3.5 mAAC at 1000 VAC/ 4.5 mADC at 1200 VDC

Internal Load

(load buttons not activated)

Approximately 2.4 W at 690 V AC/DC

Approximately 3.5 W at 1000 VAC / Approximately 5.4 W at 1200 VDC

Test Current Switchable Load

(load buttons activated)

≤350 mA AC/DC at 690 V AC/DC

≤300 mAAC at 1000 VAC / ≤350 mADC at 1200 VDC

Switchable Load

(load buttons activated)

Approximately 240 W at 690 V AC/DC

Approximately 300 W at 1000 VAC / Approximately 420 W at 1200 VDC

Automatic Power ON

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LED: >12 V (activated load buttons)

 >24 V (w/o load buttons)

LCD: >12V

LED: >12 V

LCD: > 6V

Trip Test RCD (earth leakage circuit breaker)

Test Current Switchable Load

(load buttons activated)

>30 mAAC at 230 VAC

Single Pole Phase Test

Voltage Range

180…690 VAC against earth

100…1000 VAC against earth

Frequency Range

40Hz… 70Hz

Acoustic Indication

Yes

Indication

Red LED

Continuity Test (Rx)/ Diode Test

Range

0….500 kΩ

Tolerance

0% to +50%

Test Current

<5 μA

Acoustic Indication

Yes

Diode Test

Yes

Indication

RED LED

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Automatic Power ON

< 500 kΩ

Phase Rotation Indication

Voltage Range

340…440 V AC phase to phase

170…1000 V AC phase to phase

Frequency Range

47…63 Hz

40…70 Hz

Indication

Red LED

Resistance Measurement (Ω)/ Low Resistance Indication (2100-Gamma only)

Resistance Range on LCD

0….1999 Ω

Resolution

1 Ω

Tolerance

± (5% rdg + 10 LSD) at 20°C

Temperature Coefficient

± (5 LSD / 10 K)

Test Current

<30 μA

Low Resistance Indication

Acoustic Indication <10…50Ω

Overvoltage Protection

690 V AC/DC

1000 VAC/ 1200 VDC

Non-Contact Voltage Indication/ Electric Field (NCV/EF)

Voltage Range

-

100…1000 VAC

Frequency Range

-

50…60 Hz

Indication

_

3 levels shown by LCD segments

Data Hold

Data Hold

_

Only voltage measurements (12…690V AC/DC)

Voltage and resistance measurements, NCV

Measurement Illumination Area/ Torch Light

Torch Light

White LED

General Specifications

Operation Time (DT)

30s

Recovery Time

240s

Operating Temperature

-15°C to +55°C

Storage Temperature

-15°C to +55°C

Humidity

Max. 95% RH

Operating Altitude

Up to 2000m

Safety Rating (Overall Voltage Category)

CAT IV / 600V, CAT III / 690V

CAT IV / 600V, CAT III / 1000V

Pollution Degree

2

Protection Degree

IP64

Safety Regulations

IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011

Approvals, Compliance

GS mark from TÜV Rheinland, CE

Power Supply

Battery 2 x 1.5V (AAA/ IEC LR03)

Power Consumption

Approximately 60mA

Battery Lifetime

More than 10000 measurements (<5 s/ per measurement)

Dimensions (HxWxD)

Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)

Weight

Approximately 320 g (0.71 lb)

UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE

Recently Viewed