Voltage tester with continuity measurement, phase sequence indication, resistance and NCV
Product Overview:
The Beha-Amprobe 2100-Alpha, 2100-Beta and 2100-Gamma are rugged and reliable two pole voltage testers for voltage and continuity checks. Built tough for use in industrial and commercial environments, the 2100 Series is safety rated up to CAT III 1000 V/ CAT IV 600 V and measures voltage range up to 1000 V AC and 1200 V DC (2100-Gamma only). Designed with reinforced components for dependable performance, the 2100 Series has an ingress protection degree of IP 64 and is built according to voltage tester standard EN 61243-3 and are TÜV and GS approved.

Key Features:
• Voltage test up to 1000 V, alternating current and 1200 V direct current
• Digital LCD 12…1000 V AC/ 1200 V DC
• Measures resistance up to 1999 Ohm
• Optical and acoustic continuity and voltage test
• Low resistance continuity measurement <10...50 Ohm
• Patented phase rotation indicator, no 3rd hand required
• Single-pole phase test
• Polarity
• Non-contact voltage (NCV/EF) detection
Product information
• Switchable load (load tester) of 300 W at 1000 VAC / 420 W at 1200 VDC via two push buttons, triggering a RCD/FI up to 30 mA
• IP 64, water and dust-resistant
• Integrated probe-tip protection for reducing the danger of injuries
Product highlights
• No unintentional triggering of RCD/FI circuit breakers
• Fast single-handed testing of power sockets with 19 mm contact clearance, without the probe coming away from the unit
• Lighting of measurement points via white LED
• Extremely robust construction with doubly insulated wires
 |
Two Button Switchable Load/ RCD Trip Test
|
Long, durable test leads with wear indicator
|
Test probe protector cover with accessory storage
|
When the two buttons are not pressed the unit is in high impedance mode, providing additional safety protection when testing live power sources, and avoiding accidental tripping of residual-current devices (RCD). When the buttons are pressed the unit is in low impedance mode, eliminating inaccurate readings as result of ghost voltage. Additionally, in systems with RCDs you can press the buttons to intentionally trip 10 mA or 30 mA RCDs and determine if they are wired correctly.
|
Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.
|
Extra-long 1.5 m test leads make testing fast and convenient. The two pole tester’s rugged, durable test leads have two layers of insulation for added durability and safety. If the inner, contrasting-colored layer is showing, that’s a sign that the test leads require replacement.
|
Amprobe 2100 Series Technical Specifications
|
2100-Alpha
|
2100-Beta |
2100-Gamma |
Voltage Test
|
LED Voltage Range
|
12…690 V AC/DC
|
12…690 V AC/DC
|
12…≥690 V AC/DC
|
LED Indicator
|
±12, ±24, 50, 120, 230, 400, 690 V
|
±12, ±24, 50, 120, 230, 400, ≥690 V
|
LED Tolerances
|
acc. To EN 61243-3:2010
|
LCD Voltage Range
|
-
|
12…690 V AC/DC
|
6…1000 V AC/ 6…1200 V DC
|
LCD Resolution
|
-
|
1 V
|
LCD Tolerance
|
-
|
± (3% rdg + 3 LSD)
|
LED and LCD Response Time
|
< 1s
|
Frequency Range
|
DC, 16 2/3 Hz…400 Hz
|
Acoustic Indication
|
≥ 50 V AC, ≥ 120 V DC
|
Voltage Detection
|
Automatic (AC/DC)
|
Polarity Detection
|
Full Range
|
Range Detection
|
Automatic
|
Current I
(load buttons not activated)
|
≤3.5 mA AC/DC at 690 V AC/DC
|
≤3.5 mAAC at 1000 VAC/ 4.5 mADC at 1200 VDC
|
Internal Load
(load buttons not activated)
|
Approximately 2.4 W at 690 V AC/DC
|
Approximately 3.5 W at 1000 VAC / Approximately 5.4 W at 1200 VDC
|
Test Current Switchable Load
(load buttons activated)
|
≤350 mA AC/DC at 690 V AC/DC
|
≤300 mAAC at 1000 VAC / ≤350 mADC at 1200 VDC
|
Switchable Load
(load buttons activated)
|
Approximately 240 W at 690 V AC/DC
|
Approximately 300 W at 1000 VAC / Approximately 420 W at 1200 VDC
|
Automatic Power ON
|
LED: >12 V (activated load buttons)
>24 V (w/o load buttons)
|
LED: >12 V (activated load buttons)
>24 V (w/o load buttons)
LCD: >12V
|
LED: >12 V
LCD: > 6V
|
Trip Test RCD (earth leakage circuit breaker)
|
Test Current Switchable Load
(load buttons activated)
|
>30 mAAC at 230 VAC
|
Single Pole Phase Test
|
Voltage Range
|
180…690 VAC against earth
|
100…1000 VAC against earth
|
Frequency Range
|
40Hz… 70Hz
|
Acoustic Indication
|
Yes
|
Indication
|
Red LED
|
Continuity Test (Rx)/ Diode Test
|
Range
|
0….500 kΩ
|
Tolerance
|
0% to +50%
|
Test Current
|
<5 μA
|
Acoustic Indication
|
Yes
|
Diode Test
|
Yes
|
Indication
|
RED LED
|
Overvoltage Protection
|
690 V AC/DC
|
1000 VAC/ 1200 VDC
|
Automatic Power ON
|
< 500 kΩ
|
Phase Rotation Indication
|
Voltage Range
|
340…440 V AC phase to phase
|
170…1000 V AC phase to phase
|
Frequency Range
|
47…63 Hz
|
40…70 Hz
|
Indication
|
Red LED
|
Resistance Measurement (Ω)/ Low Resistance Indication (2100-Gamma only)
|
Resistance Range on LCD
|
0….1999 Ω
|
Resolution
|
1 Ω
|
Tolerance
|
± (5% rdg + 10 LSD) at 20°C
|
Temperature Coefficient
|
± (5 LSD / 10 K)
|
Test Current
|
<30 μA
|
Low Resistance Indication
|
Acoustic Indication <10…50Ω
|
Overvoltage Protection
|
690 V AC/DC
|
1000 VAC/ 1200 VDC
|
Non-Contact Voltage Indication/ Electric Field (NCV/EF)
|
Voltage Range
|
-
|
100…1000 VAC
|
Frequency Range
|
-
|
50…60 Hz
|
Indication
|
_
|
3 levels shown by LCD segments
|
Data Hold
|
Data Hold
|
_
|
Only voltage measurements (12…690V AC/DC)
|
Voltage and resistance measurements, NCV
|
Measurement Illumination Area/ Torch Light
|
Torch Light
|
White LED
|
General Specifications
|
Operation Time (DT)
|
30s
|
Recovery Time
|
240s
|
Operating Temperature
|
-15°C to +55°C
|
Storage Temperature
|
-15°C to +55°C
|
Humidity
|
Max. 95% RH
|
Operating Altitude
|
Up to 2000m
|
Safety Rating (Overall Voltage Category)
|
CAT IV / 600V, CAT III / 690V
|
CAT IV / 600V, CAT III / 1000V
|
Pollution Degree
|
2
|
Protection Degree
|
IP64
|
Safety Regulations
|
IEC 61243-3:2009, EN 61243-3:2010, DIN VDE 0682-401:2011
|
Approvals, Compliance
|
GS mark from TÜV Rheinland, CE
|
Power Supply
|
Battery 2 x 1.5V (AAA/ IEC LR03)
|
Power Consumption
|
Approximately 60mA
|
Battery Lifetime
|
More than 10000 measurements (<5 s/ per measurement)
|
Dimensions (HxWxD)
|
Approximately 280 x 78 x 35 mm (11.0 x 3.1 x 1.4 in)
|
Weight
|
Approximately 320 g (0.71 lb)
|
|
UK Mainland
|
Order by 2pm for Next Day Delivery*
|
Under £25.00 |
£4.50 |
Over £25.00 |
FREE |
UK Highlands & Islands
|
Order by 2pm for Next Day Delivery*
|
Under £80.00 |
£15.00 |
Over £80.00 |