This instrument comes complete with the manufacturer’s calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.
The MI 3122 SMARTEC Z Line-Loop / RCD is designed specifically for live circuit testing. The instrument contains integrated characteristics of fuses and RCDs for the evaluation of test results. The online voltage monitoring system allows the operator to control what is happening on three simultaneous voltages in real-time. The bright red and green PASS / FAIL lights and help screens for each measurement make the handling of the instrument easy and clear.
All the results can be quickly saved on the instrument and then downloaded via the optional A 1291 EuroLink PRO or A 1290 EuroLink PRO Plus software for evaluation and professional report generation after testing. The MI 3122 SMARTEC Z Line-Loop / RCD performs RCD, loop, line, AC voltage, frequency and phase sequence tests required by the EN 61557 standard.
Metrel MI 3122 SMARTEC Z Line Loop RCD Technical Specification | ||
RCD Testing | ||
Nominal Residual Current (A, AC) | 10mA, 30mA, 100mA, 300mA, 500mA, 1000mA | |
Test Current Shape | Sine-Wave (AC), Pulsed (A) | |
RCD Type | G (non-delayed), S (time-delayed) | |
Test Current Starting Polarity | 0 or 180° | |
Voltage Range | 50V ÷ 264V (45Hz ÷ 65Hz) | |
Complete measuring range corresponds to EN 61557 requirements | ||
Contact Voltage | ||
Measuring Range (V) | Resolution (V) | Accuracy |
0.0 ÷ 19.9 | 0.1 | (-0%/+15%) of reading ± 10 Digits |
20.0 ÷ 99.9 | 0.1 | (-0%15%) of reading |
Test Current: max 0.5xlΔN | Limit Contact Voltage: 25V, 50V | |
Trip-Out Time | ||
Measuring Range (ms) | Resolution (ms) | Accuracy |
0 ÷ 300 | 1 | ±3ms |
Test Current: 1/2 x lΔN, lΔN, 2xlΔN, 5xlΔN | ||
Trip-Out Current | ||
Measuring Range (lΔ) | Resolution (lΔ) | Accuracy |
0.2xlΔN ÷ 1.1lΔN (AC Type) | 0.05lΔN | ±0.1xlΔN |
0.2xlΔN ÷ 1.5lΔN (A Type, IDN\30mA) | 0.05lΔN | ±0.1xlΔN |
0.2xlΔN ÷ 2.2lΔN (A Type, IDN <30mA) | 0.05lΔN | ±0.1xlΔN |
Fault Loop Impedance (no disconnecting device or FUSE selected) Measuring range according to EN 61557 is 0.25Ω ÷ 9.99kΩ |
||
Measuring Range (Ω) | Resolution (Ω) | Accuracy |
0 ÷ 9.99 | 0.01 | ±(5% of reading + 5 digits) |
10 ÷ 99.9 | 0.1 | ±(5% of reading + 5 digits) |
100 ÷ 999 | 1 | ±10% of reading |
1k ÷ 9.99k | 10 | ±10% of reading |
Test Current (at 230V): 6.5A (10ms Nominal Voltage Range: 30V ÷ 65Hz) |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |
Price £272.10 £226.75
Available In 3-7 Days
Price £5548.80 £4624.00
In Stock
Price £23.94 £19.95
Available In 3-7 Days
Price £51.94 £43.28
Available In 3-7 Days