Megger LRCD210 Loop and RCD Tester

Product Code: MEGLRCD210

Price
£555.00 ex. VAT £666.00 inc. VAT

Available In 3-7 Days


Add To Favourites
Detailed Description

Key Features:

  • RCD testing from 10 mA to 1000 mA
  • Extremely easy and safe to use
  • Built-in protective front cover
  • Tough Rubber armoured case
  • Weatherproof
  • 3 year warranty
  • Comes with Calibration Certificate

*Important Calibration Information:
This instrument comes complete with the manufacturer’s calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.

The Megger LRCD200 series is the latest generation of combined non-tripping loop tester and RCD test instruments that provide simple, affordable and flexible test tools for electrical contractors testing energised circuits


All Megger LRCD200 series instruments are supplied with a calibration certificate.

Two instruments are available: 

Megger LRCD210
This instrument provides three phase safe non-trip loop testing and 1/2I, I, and 5I RCD testing for standard, selective and DC RCDs. Suitable for domestic installers testing to UK Part P requirements.

Megger LRCD220
As the LRCD210 with the addition of 2 wire fast testing, plus phase to phase and phase to earth measurement. 

Both instruments will not trip RCDs rated at 30 mA or
greater during loop testing, even electronic RCDs.

Megger LRCD210 
Voltage Measurements 0 V - 500 V
Voltage Accuracy ±2% ±2 digits
Frequency Measurement Range 25Hz to 450Hz
Frequency Accuracy 25.0Hz to 199.9Hz ±0.1Hz
200Hz to 450Hz ±1Hz
Phase Rotation Indicator (LRCD220 only) Three wire identification of phase rotation.
Frequency 45Hz to 65Hz
Loop Testing Loop ranges (to EN 61557-3)
No-Trip Loop Test (3 Wire, Line To Earth) LRCD200/210 200V - 280 V 45Hz to 65Hz
LRCD220 100V - 280 V 45Hz to 65Hz
Nominal Test Current 15 mA
Loop Accuracy 0.01 ½ - 9.99 ½ (±5% ±0.03 ½)
10.0 ½ - 99.9 ½ (±5% ±0.5 ½)
100 ½ - 999 ½ (±5% ±5 ½)
1.00 k½ - 2.00 k½ (±5% ±30 ½)
Hi Current Line/Earth Loop Test (2 Wire, LRCD220 Only) Yes
Supply 100 V - 480 V
Nominal Test Current 15 mA to 2.4 A
Loop Accuracy 0.01½ - 9.99 ½ (±5% ±0.03 ½)
10.0½ - 99.9 ½ (±5% ±0.5 ½)
100½ - 999 ½ (±5% ±5 ½)
1.0 k½ - 2.00 k½ (±5% ±30 ½)
Line/Line (LRCD220 Only) Supply 100 V - 480 V 45Hz to 65Hz
Prospective Fault Current (PSCC) Prospective fault current = Nominal supply voltage/Loop
resistance
Accuracy is derived from loop test
1 A - 199 A 1 A resolution
0.20 kA - 1.99 kA 10 A resolution
2.0 kA - 19.9 kA 100 A resolution
RCD Testing RCD Test Ranges (to EN61557-6)
LRCD200/210 10mA, 30mA,100mA, 300mA, 500mA
LRCD220 10mA, 30mA,100mA, 300mA, 500mA, 1000mA
Supply Voltage LRCD200/210 = 200 V - 280 V 45Hz to 65Hz
LRCD220 = 100 V - 280 V 45Hz to 65Hz

Megger LRCD210 
Voltage Measurements 0 V - 500 V
Voltage Accuracy ±2% ±2 digits
Frequency Measurement Range 25Hz to 450Hz
Frequency Accuracy 25.0Hz to 199.9Hz ±0.1Hz
200Hz to 450Hz ±1Hz
Phase Rotation Indicator (LRCD220 only) Three wire identification of phase rotation.
Frequency 45Hz to 65Hz
Loop Testing Loop ranges (to EN 61557-3)
No-Trip Loop Test (3 Wire, Line To Earth) LRCD200/210 200V - 280 V 45Hz to 65Hz
LRCD220 100V - 280 V 45Hz to 65Hz
Nominal Test Current 15 mA
Loop Accuracy 0.01 ½ - 9.99 ½ (±5% ±0.03 ½)
10.0 ½ - 99.9 ½ (±5% ±0.5 ½)
100 ½ - 999 ½ (±5% ±5 ½)
1.00 k½ - 2.00 k½ (±5% ±30 ½)
Hi Current Line/Earth Loop Test (2 Wire, LRCD220 Only) Yes
Supply 100 V - 480 V
Nominal Test Current 15 mA to 2.4 A
Loop Accuracy 0.01½ - 9.99 ½ (±5% ±0.03 ½)
10.0½ - 99.9 ½ (±5% ±0.5 ½)
100½ - 999 ½ (±5% ±5 ½)
1.0 k½ - 2.00 k½ (±5% ±30 ½)
Line/Line (LRCD220 Only) Supply 100 V - 480 V 45Hz to 65Hz
Prospective Fault Current (PSCC) Prospective fault current = Nominal supply voltage/Loop
resistance
Accuracy is derived from loop test
1 A - 199 A 1 A resolution
0.20 kA - 1.99 kA 10 A resolution
2.0 kA - 19.9 kA 100 A resolution
RCD Testing RCD Test Ranges (to EN61557-6)
LRCD200/210 10mA, 30mA,100mA, 300mA, 500mA
LRCD220 10mA, 30mA,100mA, 300mA, 500mA, 1000mA
Supply Voltage LRCD200/210 = 200 V - 280 V 45Hz to 65Hz
LRCD220 = 100 V - 280 V 45Hz to 65Hz