Detailed Description

Supplied With:

  • Bag
  • Battery (mounted)
  • SD card
  • Red banana voltage lead
  • Black banana voltage lead
  • 1x MA194-250 flexible AC currentsensor
  • 2x Crocodile clips
  • Type-C7 power supply cable
  • C8 adapter
  • Safety datasheet
  • Test report
  • Multilingual Quick Start Guide
  • Multilingual User's Manual Available for download from Chauvin Arnoux website
  • Data transfer and management software available for download from Chauvin Arnoux website

*Important Calibration Information: 
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.[Text Wrapping Break]Where calibration of an instrument is possible we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required. 

Dataview

The PEL51 power logger and energy meter provides a simple but comprehensive solution for electricians seeking to monitor consumption in the context of energy savings or to improve a building's energy efficiency



Product Description:

The compact PEL51 fits in one hand and is easy to handle. Its magnetized casing allows you to position it in smaller electrical cabinets where space is at a premium. No need to cut off the mains to start using it. In addition, it is self-powered via the phase, making it ideal for long campaigns. The backlit multi-display LCD screen is particularly easy to read and is equipped with one channel for the following single-phase measurements:

  • TRMS voltage and current measurement
  • Power measurement: W (P, Pf), [JP1] VA and var (N, Q1 and D)
  • Measurement of PF, DPF, CF and THD
  • All the data is recorded on an SD card [JP2] 
  • The PEL51 offers multiple communication modes for real-time monitoring or for saving measurement results:

    • Wifi communication
    • Integrated web server
    • PEL Transfer® software for data back-up, real-time display and analysis

   600v_catIII   ip54sd_card   wifi   server

Energy efficiency and measurement of the savings

When a building or factory is the focus of a global energy survey, electricity consumption is often less than fuel oil or gas consumption, etc. All companies and electricity users have a main meter at the supplier’s point of delivery (RTE in France), but they only very rarely have submetering and may suffer from the absence of a metering point at any time.
The PEL loggers are placed on these points to perform the measurements. The French RE2020 environmental regulations have tightened the constraints for checking and controlling energy spending. Mandatory audits of large companies impose these checks on them. As a result, a number of major groups have failed in their attempts to achieve ISO 50001 certification, which takes this obligation into account and goes even further in terms of seeking out energy savings.

The recordings made with PEL50 electrical measuring instruments are time/date-stamped. This means it is possible to measure the economic gains achieved simply by comparing the recordings made before and after modifications on an installation. The analysis of the recordings made with the PEL50 before the modifications corresponds to a representative period of use. The various operations for maintenance and improvement of the electrical network and equipment, or other purposes, can then be carried out.
A correctly-positioned PEL50 enables you to quickly locate the most crucial points without wasting time. A monitoring period will allow you to establish whether the solutions proposed are correct and sufficient, but above all to precisely measure the savings achieved.

Power Measurements

  • Active power P (W)
  • Fundamental active power Pf(W)
  • Fundamental reactive power Qf (var)
  • Non-active power N (var)
  • Distortion power D (var)
  • Apparent power S (VA).
  • And all the related energy measurements.

Recording

  • The aggregated measurements are recorded over periods from 1 min to 1 hour on an SD or SDHC card. The data can be read directly on a PC.

MA194/250 Current Clamp

  • Flexible current sensor
  • IEC 61010 1000V CAT III et 600V CAT IV
Description

Current clamps, MiniFlex® and AmpFlex® flexible current sensors are used to measure the current flowing in a cable without opening the circuit. They also insulate the user from dangerous voltages in the circuit.

 

 

MiniFlex® MA194 250 mm
Measurement range 100 mA - 10 000 A 
Clamping diameter 70 mm
Dimensions (L x l x H) environ 130 x 80 x 18 mm
Cord 3 metres long
Weight approx. 110 g

MA184-250-h

Chauvin Arnoux PEL51/52 Technical Specifications
General functions
Display Multi-display backlit LCD
Types of installations Single-phase (PEL51) Split-phase or 2 single-phase channels (PEL52)
Number of channels 1V/1I (PEL51)  2V/2I (PEL52)
Models PEL51/52
General functions
Network frequency 50 and 60 Hz
Voltage 10 V to 600 V
Current range See table on previous page
Ratios Yes
Power/energy values P, Pf, N, S, Qf, D / Up to 4 Exa
Min – Max Yes
THD Yes
Additional functions
Acquisition rate 1 measurement / s
Aggregation 1 min to 60 min
Storage mode SD / SD-HC card 8 GB (expandable to 32 GB)
Ethernet Yes (via simplified Wifi)
Safety IEC 61010 CAT III 600 V
Power supply Via the measurement phase (90 – 600 V)
Battery NiMH – Battery life 1 hour
Dimensions 180 x 88 x 37 mm
Weight 400 g
Casing IP54