Troubleshooting in one total solution
This combo kit pairs the Fluke 117 DMM with a Fluke 323 clamp meter for productive and effective troubleshooting in one total solution, including the C115 durable soft carrying case for protection and easy meter transportation.
Fluke 117/323 Combo Kit Includes:
- Fluke 117 Digital Multimeter
- Fluke 323 True-rms Clamp Meter
Fluke117 Digital Multimeter. Designed by Electricians. Engineered by Fluke.
- VoltAlert™ technology for non-contact voltage detection.
- AutoVolt automatic ac/dc voltage selection.
- Low input impedance: Helps prevent false readings due to ghost voltage.
- Large white LED backlight to work in poorly lit areas.
- True-rms for accurate measurements on non-linear loads.
- Measures 10 A (20 A overload for 30-seconds).
- Resistance, continuity, frequency and capacitance.
- Min/Max/Average to record signal fluctuations.
- Compact ergonomic design for one-handed operation.
- CAT III 600 V safety rated.
Fluke 323 True-rms Clamp Meter. Rugged. Reliable. Precise.
- 400 A ac current measurement.
- 600 V ac and dc voltage measurement.
- True-rms ac voltage and current for accurate measurements on non-linear signals.
- Resistance measurement up to 40 kΩ with continuity detection.
- Slim, ergonomic design.
- CAT IV 300V/CAT III 600 V safety rating.
Specifications |
Maximum voltage between any terminal and earth ground |
600 V |
Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
Fuse for A input |
11 A, 1000 V FAST Fuse (Fluke PN 803293) |
Display |
Digital: |
6,000 counts, updates 4 per second |
Bar graph |
33 segments, updates 32 per second |
Operating Temperature |
-10 °C to + 50 °C |
Storage Temperature |
-40 °C to + 60 °C |
Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
Battery Life |
400 hours typical, without backlight |
Accuracy Specifications |
DC millivolts |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
DC volts |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.00 V / 0.1 V |
Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
Auto volts |
Range |
600.0 V |
Resolution |
0.1 V |
Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
AC millivolts1 true-rms |
Range |
600.0 mV |
Resolution |
0.1 mV |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
AC volts1 true-rms |
Range/Resolution |
6.000 V / 0.001 V |
Range/Resolution |
60.00 V / 0.01 V |
Range/Resolution |
600.0 V / 0.1 V |
Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
Continuity |
Range |
600 Ω |
Resolution |
1 Ω |
Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
Range/Resolution |
6.000 kΩ / 0.001 kΩ |
Range/Resolution |
60.00 kΩ / 0.01 kΩ |
Range/Resolution |
600.0 kΩ / 0.1 kΩ |
Range/Resolution |
6.000 MΩ / 0.001 MΩ |
Accuracy |
0.9 % + 1 |
Range/Resolution |
40.00 MΩ / 0.01 MΩ |
Accuracy |
5 % + 2 |
Diode Test |
Range/Resolution |
2.000 V / 0.001 V |
Accuracy |
0.9% + 2 |
Capacitance |
Range/Resolution |
1000 nF / 1 nF |
Range/Resolution |
10.00 μF / 0.01 μF |
Range/Resolution |
100.0 μF / 0.1 μF |
Range/Resolution |
9999 μF / 1 μF |
Range/Resolution |
100 μF to 1000 μF |
Accuracy |
1.9% + 2 |
Range/Resolution |
> 1000 μF |
Accuracy |
5% + 20% |
LoZ capacitance |
Range |
1 nF to 500 μF |
Accuracy |
10% + 2 typical |
AC amps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
6.000 A / 0.001 A |
Range/Resolution |
10.00 A / 0.01 A |
Accuracy |
1.5% + 3 20 A continuous overload for 30 seconds max |
DC amps |
Range/Resolution |
6.000 A / 0.001 A |
Range/Resolution |
10.00 A / 0.01 A |
Accuracy |
1.0% + 3 20 A continuous overload for 30 seconds max |
Hz (V or A input)2 |
Range/Resolution |
99.99 Hz / 0.01 Hz |
Range/Resolution |
999.99 Hz / 0.1 Hz |
Range/Resolution |
9.999 Hz / 0.001 Hz |
Range/Resolution |
50.00 Hz / 0.01 Hz |
Accuracy |
0.1% + 2 |
Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
Mechanical & General Specifications |
Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
Weight |
550 g |
Warranty |
3 years |
Fluke 323 True-rms Clamp Meter
Specifications |
AC current |
Range 400.0 A |
|
Accuracy |
2 % ± 5 digits (45 Hz to 65 Hz) 2.5 % ± 5 digits (65 Hz to 400 Hz) |
AC voltage |
Range |
600.0 V |
Accuracy |
1.5 % ± 5 digits |
DC voltage |
Range |
600.0 V |
Accuracy |
1.0 % ± 5 digits |
Resistance |
Range |
400.0 Ω/ 4000 Ω |
Accuracy |
1.0 % ± 5 digits |
Continuity |
≤ 70 Ω |
AC response |
True-rms |
Data hold |
Yes |
Size |
H x W x D (mm) |
207 x 75 x 34 |
Max wire diameter |
30 mm (600 MCM) |
Weight |
265 g |
Category rating |
CAT III 600 V CAT IV 300 V |
Warranty |
Two-year |
|
UK Mainland
|
Order by 2pm for Next Day Delivery*
|
Under £25.00 |
£4.50 |
Over £25.00 |
FREE |
UK Highlands & Islands
|
Order by 2pm for Next Day Delivery*
|
Under £80.00 |
£15.00 |
Over £80.00 |
FREE |