For Every HVAC professional
For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.
Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.
- Fluke 116 HVAC Multimeter with Temperature and Microamps.
- TL175 Hard Point Test Lead Set.
- TPak ToolPak Magnetic Meter Hanging Strap.
- Flexible Cuff Pipe Clamp Thermocouple.
- 80BK Integrated Temperature Probe.
- 80AK-A Thermocouple Adapter.
- C115 Deluxe Soft Carrying Case with Shoulder Strap.
Fluke 62 MAX+. Small in size. Big on toughness.
- Dust and water-resistant: IP54 rated.
- Rugged: 3-meter (9.8-foot) drop tested.
- Ergonomically designed: Completely redesigned for a more natural hand fit.
- Distance to spot: 12:1.
- Dual lasers: Identifies area to be measured.
- Large, backlit display: Makes data easier to read, even in dark areas.
| Specifications |
| Maximum voltage between any terminal and earth ground |
600 V |
| Surge protection |
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2 |
| Display |
6,000 counts, updates 4 per second |
| Bar graph |
33 segments, updates 32 per second |
| Operating Temperature |
-10 °C to + 50 °C |
| Storage Temperature |
-40 °C to + 60 °C |
| Battery type |
9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Battery Life |
400 hours typical, without backlight |
| Accuracy Specifications |
| DC millivolts |
Range |
600.0 mV |
| Resolution |
0.1 mV |
| Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
| DC volts |
Range/Resolution |
6.000 V / 0.001 V |
| Range/Resolution |
60.00 V / 0.01 V |
| Range/Resolution |
600.00 V / 0.1 V |
| Accuracy |
± ([% of reading] + [counts]): 0.5% + 2 |
| Auto volts |
Range |
600.0 V |
| Resolution |
0.1 V |
| Accuracy |
2.0 % + 3 (dc, 45 Hz to 500 Hz) 4.0 % + 3 (500 Hz to 1 kHz) |
| AC millivolts1 true-rms |
Range |
600.0 mV |
| Resolution |
0.1 mV |
| Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| AC volts1 true-rms |
Range/Resolution |
6.000 V / 0.001 V |
| Range/Resolution |
60.00 V / 0.01 V |
| Range/Resolution |
600.0 V / 0.1 V |
| Accuracy |
1.0 % + 3 (dc, 45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) |
| Continuity |
Range |
600 Ω |
| Resolution |
1 Ω |
| Accuracy |
Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer. |
| Ohms |
Range/Resolution |
600.0 Ω / 0.1 Ω |
| Range/Resolution |
6.000 kΩ / 0.001 kΩ |
| Range/Resolution |
60.00 kΩ / 0.01 kΩ |
| Range/Resolution |
600.0 kΩ / 0.1 kΩ |
| Range/Resolution |
6.000 MΩ / 0.001 MΩ |
| Accuracy |
0.9 % + 1 |
| Range/Resolution |
40.00 MΩ / 0.01 MΩ |
| Accuracy |
1.5 % + 2 |
| Diode Test |
Range/Resolution |
2.000 V / 0.001 V |
| Accuracy |
0.9% + 2 |
| Capacitance |
Range/Resolution |
1000 nF / 1 nF |
| Range/Resolution |
10.00 μF / 0.01 μF |
| Range/Resolution |
100.0 μF / 0.1 μF |
| Range/Resolution |
9999 μF / 1 μF |
| Range/Resolution |
100 μF to 1000 μF |
| Accuracy |
1.9% + 2 |
| Range/Resolution |
> 1000 μF |
| Accuracy |
5% + 20% |
| LoZ capacitance |
Range |
1 nF to 500 μF |
| Accuracy |
10% + 2 typical |
| Temperature2 (Type-K thermocouple) |
Range/Resolution |
-40 °C to 400 °C / 0.1 °C |
| Accuracy |
1% + 102 |
| Range/Resolution |
-40 °F to 752 °F / 0.2 °F |
| Accuracy |
1% + 182 |
| AC μamps true-rms (45 Hz to 500 Hz) |
Range/Resolution |
600.0 μA / 0.1 μA |
| Accuracy |
1.0% + 2 |
| DC μamps |
Range/Resolution |
600.0 μA / 0.1 μA |
| Accuracy |
1.0% + 2 |
| Hz (V or A input)2 |
Range/Resolution |
99.99 Hz / 0.01 Hz |
| Range/Resolution |
999.99 Hz / 0.1 Hz |
| Range/Resolution |
9.999 Hz / 0.001 Hz |
| Range/Resolution |
50.00 Hz / 0.01 Hz |
| Accuracy |
0.1% + 2 |
Notes: 1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V. 2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe. 3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current. 4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F
| Mechanical & General Specifications |
| Size |
167 x 84 x 46 mm (6.57" x 3.31" x 1.82") |
| Weight |
550 g |
| Warranty |
3 years |
Fluke 62 MAX+ Infrared Thermometer
| Specifications |
|
Temperature Range
|
-30 °C to 650 °C (-22 °F to 1202 °F) |
| Accuracy |
±1.0 °C or ±1.0% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 |
| Response Time (95%) |
Fluke 62+ MAX |
<300 ms (95% of reading) |
| Spectral Response |
8 to 14 microns |
| Emissivity |
0.10 to 1.00 |
|
Optical Resolution
|
12:1 (calculated at 90% energy) |
| Display Resolution |
0.1 °C (0.2 °F) |
| Repeatability of Readings |
±0.5% of reading or <±0.5 °C (1 °F), whichever is greater |
| Power |
AA battery |
| Battery Life |
8 hours with laser and backlight on |
| Physical Specifications |
Weight |
255 g (8.99 oz) |
| Size |
(175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
| Operating Temperature |
0 °C to 50 °C (32 °F to 122 °F) |
| Storage Temperature |
-20 °C to 60 °C (-4 °F to 140 °F), (without battery) |
| Operating Humidity |
10 % to 90 % RH non-condensing at 30 °C (86 °F) |
| Operating Altitude |
2000 meters above mean sea level |
| Storage Altitude |
12,000 meters above mean sea level |
| IP Rating |
IP 54 per IEC 60529 |
| Drop Test |
3 meters |
| Vibration and Shock |
IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms |
| EMC |
EN 61326-1:2006 EN 61326-2:2006 |
|
Standards and Agency Approval
|
Compliance |
EN/IEC 61010-1: 2001 |
| Laser Safety |
FDA and EN 60825-1 Class II |
|
|
UK Mainland
|
Order by 2pm for Next Day Delivery*
|
| Under £25.00 |
£4.50 |
| Over £25.00 |
FREE |
|
UK Highlands & Islands
|
Order by 2pm for Next Day Delivery*
|
| Under £80.00 |
£15.00 |
| Over £80.00 |
FREE |