This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible, we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.
The Amprobe 5XP-A digital multimeter provides superior features and accuracy in a smaller form factor. The 5XP-A has unique features such as VolTect™ non-contact voltage (NVC) detection and our exclusive Magne-Grip™ holster that frees both hands for work. The 5XP-A is the right choice for residential, commercial and general troubleshooting applications.
DC Voltage Ranges | 200 mV, 2 V, 20 V, 200 V, 1000 V Accuracy: ± (1.0 % rdg + 1 dgt) |
AC Voltage (45 to 500Hz) Ranges | 200 mV, 2 V, 20 V, 200 V, 750 V Accuracy: ± (1.5 % rdg + 5 dgts) |
Voltage Resolution | 100 µV |
Voltage Input Impedance | 10 MO |
Overload Protection | 200 mV: 1000 V dc or 750 V ac rms (3 minutes) All other ranges: 1000 V dc or 750 V ac rms |
DC Current Ranges | 200 µA, 2 mA, 20 mA, 200 mA Accuracy: ± (1.5 % rdg + 1 dgt) |
AC Current (45 to 500Hz) Ranges | 200 µA, 2 mA, 20 mA, 200 mA Accuracy: ± (2.0 % rdg + 5 dgts) |
Current Resolution | 0.1 µA |
Input Protection | 315 mA/1000 V fast blow ceramic fuse 6.3 mm x 32 mm on mA input |
Burden Voltage | 300 mV max. (1 V max. on 200 mA range) |
Resistance |
200 O , 2 kO , 20 kO , 200 kO ± (1.0 % rdg + 4 dgts)
|
Resistance Resolution | 100 mO |
Open Circuit Voltage | 0.3 V dc typical, (3.0 V dc on 200 O range) |
Overload Protection | 1000 V dc or 750 V ac rms |
Continuity Audible Indication | 75 O ± 25 O, Response Time: 100 ms |
Diode Test Current | 1.0 mA (approximate) ±(1.5 % rdg + 3 dgts) |
Diode Test Resolution | 1 mV |
Open Circuit Voltage | 3.0 V dc typical |
Non-Contact Voltage Indicator | Sense voltage 70 V to 600 V ac; beeper chirps and bright red LED on, works on all ranges |
Battery Test | 1.5 V, 9 V Accuracy: ± (3.5 % rdg + 2 dgts) |