Megger EVCA210 Electric Vehicle Charge point Adaptor 1012-732

Product Code: MEG1012-732

Price
£320.00 ex. VAT £384.00 inc. VAT

In Stock


Add To Favourites
Detailed Description

Key Features:

  • Push Button for PE Pre-Test
  • Push button for CP Error “E” simulation
  • Push button for PE Error (Earth Fault) simulation
  • Rotary switch providing PP State simulation
  • Rotary Switch providing CP State simulation
  • Type 2 Charging Plug for charging points with panel mounted socket outlet or fixed cable with vehicle connector
  • Type 1 Charging Plug for charging points with fixed cable and vehicle connector
  • (Example Mitsubishi PHEV) – option for the EVCA210/standard on the EVCA210-UK
  • IP54 Rating & Carrying Case
  • CAT II 300V Rating
  • Comply with Low Voltage Directive LVD 2014/35

The Megger EVCA210 is a compact, simple to use adapter designed to perform all the functions required by the electrical contractor to fully test Mode 3 AC Electric Vehicle Charge-points.

The Megger EVCA210/EVCA210-UK are compact, simple to use adapters designed to perform all the functions required by the electrical contractor to fully test Mode 3 AC Electric Vehicle Charge-points. Specially designed to comply with UK, European and other International wiring regulations and standards, the EVCA210/EVCA210-UK may be used on all single and three phase electric vehicle charge points, with appropriate connectors. They are designed to test the function and safety of a charging point. The adapters allow you to conduct tests using appropriate single or multifunction test instruments on EV charging points in accordance with IEC/EN 61851-1 and IEC/HD 60364-7-722. Charging points should be tested as part of the initial installation and repeated periodically.
The Megger EVCA210/EVCA210-UK test adaptors are designed to simulate the connection of an electrical vehicle to the charging point under test. Connection of the adapter enables the operator to trigger the charging process by selecting the appropriate Proximity Pilot (PP) and Control Pilot (CP) states.
Test instruments can be connected using either the front mounted mains socket or the 4mm connection ports L1, L2, L3, N, PE. 2 additional CP signal terminals give the operator the ability to measure the CP signal using an oscilloscope. In addition, the adapters have a manual PE Pre-Test feature that allows the user to test for dangerous voltages present on the PE, prior to any other testing of the charge point. If this test fails, testing must cease as potentially dangerous voltages may be present on the PE and faults must be investigated and rectified before continuing. The adapters also integrate two further manual tests: CP Error – simulates an error on the control pilot circuit; and a PE Error – where a disconnection of the PE circuit is produced. Both test ensure correct disconnection of the output of the charge point.Before carrying out testing with this adaptor, it is recommended that the user familiarize themselves with the relevant standards: IEC 61851-1:2017, Electric vehicle conductive charging system - Part 1: General requirements
IEC 60364-7-722:2018 Low-voltage electrical installations - Part 7-722: Requirements for special installations or locations - Supplies for electric vehicles and any documentation relating to the charging station itself.The Megger EVCA210-UK is provided with 2 connection cables as standard, a Type 2 connector for charging points with panel mounted socket outlet or fixed cable with vehicle connector and a Type 1 connector for charging points with fixed Type 1 cable connector – as found on the Mitsubishi PHEV.The Megger EVCA210 is supplied with the Type 2 plug only.


EVCA210-UK Comes Supplied With:

  • Type 1 Charging Plug
  • Type 2 Charging Plug
  • EVCA210 Carry Case
  • Instruction Manual



EVCA210 EVCA210-UK
Input voltage 250 V (single phase system) / 430 V (three phase system) Y Y
Rotary switch providing PP State simulation Y Y
Rotary Switch providing CP State simulation Y Y
Push button for CP Error “E” simulation Y Y
Push button for PE Error (Earth Fault) simulation Y Y
Measurements on live conductors (L1, L2, L3 and N) and on PE conductor Y Y
Mains Socket: EVCA210-UK - 13A UK socket EVCA210 - Schuko socket (CEE 7/3) Y Y
CP signal test, two 4 mm ports for connection to an oscilloscope Y Y
CAT II 300 V Y Y
IP Rating IP54 Y Y
Type 2 Plug for charging points with panel mount-ed socket outlet or fixed cable with vehicle connector. Y Y
Type 1 Plug for charging points with fixed cable and vehicle connector – Supplied with EVCA210-UK as standard
*EVCA-210 (non UK Version) comes with only a type 2 charging plug.
Y
Soft Carry Case Y Y



Optional accessories for EVCA210 & EVCA210-UK (Included):

  • Soft Carry Case 1013-318
  • Type 1 Charging Plug 1013-319
  • Type 2 Charging Plug 1013-320
Megger EVCA210 Charge point Adapter Technical Specification
Input Voltage Up to 250 V (single phase system) / up to
430 V (three phase system)
Input Frequency 50/60 Hz
PE Pre-Test Yes - Push button
CP Error “E” Simulation Push button
PP Simulation NC, 13 A, 20 A, 32 A, 63 A
CP States A, B, C, D
CP Error “E” Yes
PE Error (Earth Fault) Yes
Measuring Ports L1, L2, L3, N and PE Max. 250/430 V, CAT II 300 V, max. 10 A
Mains Socket Max. 250 V, CAT II 300 V max. 10 A,
Note: Do not load mains socket
simultaneously with measuring ports!
CP Signal Test Ports Approx. +/-12 V, CAT 0 (under normal
condition)
In case of wrong wiring or error of the
charging station these terminals
Measurement Category CAT II 300 V
Altitude Above Ssea Level. 2000 m max
Weight Approx: 780g
IP-Rating IP54
CE Directive Low Voltage Directive LVD 2014/35/EU
Safety IEC/EN 61010-1:2010
IEC/EN 61010-2-030:2010
Working Temperature Range 0 ... +40 °C
Storage Temperature Range -10 ... +50 °C
Reference Humidity Range 10 ... 60% relative humidity w/o condensation