Kewtech KT65DL Pro Kit Multifunction Tester

Product Code: KEWKT65PROKT

Price
£775.00 ex. VAT £930.00 inc. VAT

Available In 3-7 Days


Add To Favourites
Detailed Description

Key Features:

  • Continuity - switchable buzzer and auto null
  • Insulation - 250, 500 & 1000 V with voltage warning LED and auto discharge
  • Loop - ATT (low current), high current 0.01 & 0.001 ohm resolution
  • Phase to phase loop test & 55 V loop test for CTE transformers
  • Easy PFC & PSC measurement without the need to alter test probes
  • RCD - Type AC, A, ACS, AS, auto & ramp at 10, 30, 100, 300 & 500mA
  • Auto-test memory for RCD testing with all results shown on one screen, so no scrolling
  • Phase Rotation
  • Earth resistance facility (ACCESKIT - optional earth spike kit)
  • Memory for test lead resistance compensation
  • PAT testing function with download facility
  • Polarity check
  • Advanced memory with free software

*Important Calibration Information:
This instrument comes complete with the manufacturer’s calibration certificate. Please be aware that these certificates are generic and may also be time lapsed. If you would prefer a personalised full traceable calibration certificate applied to the equipment before dispatch, then please select this option from the drop-down menu above, an additional calibration charge will apply.

Free Gifts

This instrument comes complete with your choice of free gift from the drop-down menu above. Choose from a calibration voucher for next 
year or a 50m R2 wander lead. How about a quality socket tester or lock off kit? 
Whatever you choose you can be sure you're getting a fantastic deal at Instrument Sales & Service.

Overview:

The KT65DL advanced Multifunction Tester has the feature set to test domestic, commercial and industrial installations and has a well-earned reputation for reliability, repeatability and ruggedness.

Kewtech’s loop circuits are all well designed to overcome noise, RCD uplift and contact resistance and the KT65DL is no exception. This tester also offers 0.001 ohm resolution in high current mode and max Zs tables including the 80% rule.

For PAT testing use the PAT ADAPTER1 and for earth resistance testing use the ACCES KIT.

The KT65DL comes with CD-ROM software but if you would prefer to download the KEW REPORT software you can do so here…Download Software.

Key Benefits:

  • Easy to use with straight forward interface
  • Best loop performance accuracy when benchmarked against other brands
  • 0.001 Ohm high current loop test for when you are close to the supply transformer
  • Auto RCD tests with all results on one screen
  • Selectable Max Zs tables for MCBs and Fuses so you can automatically compare with measured result on site
  • No Bangs - continuous live monitoring means no blown fuses or PCBs
  • Advanced memory means that you can tag a measurement to a site, distribution board, circuit number and type of test - for instance was that loop test a Ze or Zs?
  • Anti-Trip Technology for full no trip Loop testing on all RCD types with very low susceptibility of RCD uplift and noise interference
  • Constant live voltage detection protects when dead testing
  • Test probe with remote test button as well as lockdown test button for ‘hands free’ testing
  • KT65DL / KT66DL - only MFT's on the market to have a built in lid to protect your screen from damage, water and dust ingress
  • End of line calibration certificate
  • Comes in a soft carry case with mains lead, distribution board leads, remote test probe and software

Kewtech KT65DL Multifunction Tester

Continuity

Open Circuit
Voltage (DC)
Short Circuit
Current
Range Accuracy
5V±20% Greater than
200mA
20 / 200 / 2000Ω
Auto-Ranging
0 ~ 0.19Ω
0.2 ~ 2000Ω
±0.1Ω
±(2%rdg+8dgt)


Insulation Resistance

Open Circuit
Voltage (DC
Rated Circuit
Current
Range Accuracy
250V+40% -0% 1mA or greater @ 250kΩ 20 / 200MΩ Auto-Ranging 20 ~ 200MΩ
±(5%rdg+6dgt)
500V+30% -0% 1mA or greater @ 500kΩ 20 / 200 / 2000MΩ Auto-Ranging 200 ~ 2000MΩ
±(5%rdg+6dgt)
1000V+20% -0% 1mA or greater @ 1MΩ 20 / 200 / 2000MΩ Auto-Ranging 200 ~ 2000MΩ
±(5%rdg+6dgt)


Loop Impedance

Function Rated Voltage Nominal Test Current at 0Ω External Loop: Magnitude/ Duration Range Accuracy
L-PE 100 ~ 260V
50/60Hz
20Ω: 6A/20ms
200Ω: 2A/20ms
2000Ω: 15mA/360ms
20 / 200 / 2000Ω
Auto-Ranging
±(3%rdg+4dgt)
L-PE (ATT) 100 ~ 260V
50/60Hz
L-N: 6A/30ms
N-PE: 10mA
approx. 4s
20 / 200 / 2000Ω
Auto-Ranging L-N
< 20Ω
±(3%rdg+6dgt)
L-N/L-L 100 ~ 500V 50/60Hz 20Ω: 6A/20ms 20Ω ±(3%rdg+4dgt)


PSC (L-N/L-L) / PFC (L-PE)

PSC 100~500V
50/60Hz
6A/20ms 2000A/20kA
Auto-Ranging
PSC accuracy is derived from measured loop impedance specification and measured voltage specification
PFC 100~260V
50/60Hz
6A/20ms
2A/20ms
15mA/360ms
2000A/20kA
Auto-Ranging
PFC (ATT) 100~260V 50/60Hz L-N: 6A/30ms N-PE: 10mA/approx. 4s 2000A/20kA Auto-Ranging


RCD

Function Rated Voltage Accuracy
Trip Current Trip Time
AC Type A Type
X1/2 230V+ 10%-15% 50/60Hz -8%~2% ±10% ±(1%rdg+3dgt)
X1 +2%~+8%
X5 +2%~+8%
Ramp ±4%
Auto Depending on the accuracy at each function
Measurement sequence:
X1/2 0˚->X1/2 180˚->X1 0˚->X1 180˚-> X5 0˚-> X5 180˚
Measurements with X5 aren’t carried out when current is 300mA or more
Continuity / Insulation / Loop / PSC ranges uses the rolling average


Earth

Measuring Frequency Range Accuracy
825Hz 20/ 200 / 2000Ω Auto-Ranging 20Ω range: ±(3%rdg+0.1dgt) 200 / 2000Ω range: ±(3%rdg+3dgt) (Auxiliary earth resistance 100±5%)


Phase Rotation

Rated Voltage Remarks
50-500V 50/60Hz Correct phase sequence: are displayed “1.2.3” and mark
Reversed-phase sequence: are displayed “3.2.1” and mark


Volts

Function Rated Voltage Range Accuracy
Volts 25~500V
45~65Hz
25~500V ±(2%rdg+4dgt)
Frequency 25~500V
45~65Hz
45~65Hz ±(0.5%rdg+2dgt)
UK Mainland Order by 2pm for Next Day Delivery*
Under £25.00 £4.50
Over £25.00 FREE

UK Highlands & Islands Order by 2pm for Next Day Delivery*
Under £80.00 £15.00
Over £80.00 FREE