Product Code: MEG1004-742
Available In 3-7 Days
*Important Calibration Information:
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible, we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.
The Megger MIT480 series instruments have been developed specifically for the telecommunications industry. The insulation and continuity testers combine the latest range of measurement techniques with new instrument design to provide a state-of-the-art tester that is compact and comfortable to hold. The MIT480 series directly replaces the well-established BM80 product group, given greater functionality with simplified operation and greater application range.
MIT480 50 V, 100 V tester MIT481 50 V, 100 V, 250 V, 500 V, 1000 V tester MIT485 As 481 plus downloading results
Megger MIT485 Telecoms Insulation and Continuity Tester | ||
Insulation | ||
Test voltage | ||
Nominal | MIT481/2 and MIT485/2 50 V, 100 V, 250 V, 500 V |
|
Insulation accuracy | ||
50 Volts. 10 GΩ ± 2% ± 2 digits ± 4.0% per GΩ 100 Volts. 20 GΩ ± 2% ± 2 digits ± 2.0% per GΩ 250 Volts. 50 GΩ ± 2% ± 2 digits ± 0.8% per GΩ 500 Volts. 100 GΩ ± 2% ± 2 digits ± 0.4% per GΩ |
||
Service Error: BS EN 61557-2 (2007). | 50V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.5% 100V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 250V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% 500V, ± 2.0% ± 2d, 100kΩ - 900kΩ ± 10.3% |
|
Display range | Analogue: 1 GΩ full scale | |
Resolution | 0.1 kΩ | |
Short circuit/charge current | 2 mA +0% -50% to EN 61557-2 (2007) |
|
Open circuit voltage insulation |
-0% +2% ± 2 V | |
Test current | 1 mA at min. pass value of insulation to a maximum of 2 mA max. EN61557 Operating range: 0.10 MΩ to 1.0 0GΩ |
|
Leakage Current | 10% ±3 digits | |
Timer control | Countdown timer 60 second | |
Note | Above speci?cations only apply when high quality silicone leads are being used. |
|
Continuity | ||
Continuity range | 0.01 Ω to 1.0 MΩ | |
Continuity accuracy | ± 3% ± 2 digits (0 to 100 Ω) ±5% ±2 digits (>100 Ω- 500 kΩ) (>500 kΩ - 1 MΩ unspeci?ed) Service Error: BS EN 61557-4 (2007) - ± 2.0%, 0.1Ω - 2Ω ± 6.8% |
|
Open circuit voltage | 5 V ± 1 V | |
Test current | 200 mA (–0 mA +20 mA) (0.01 Ω to 4 Ω) |
|
Lead resistance | Nulling up to 10 Ω | |
Voltage range | ||
Voltage range | AC: 10 mV to 600 V TRMS sinusoidal (15 Hz to 400 Hz) DC: 10 mV to 600 V |
|
Volt range accuracy | AC: ± 2% ± 2 digits DC: ± 2% ± 2 digits Service Error: BS EN 61557-1 (2007) - ± 2.0% ± 2d, 0V - 300Vac/dc ± 5.1% |
|
Waveform | Unspeci?ed range: 0 – 10 mV (15 to 400 Hz) For non-sinusoidal waveforms additional specifications apply: Non-sinusoidal waveforms: ±3% ± 2 digits >100 mV to 600 V TRMS ±8% ± 2 digits 10 mV to 100 mV TRMS |
|
Default voltmeter | Operates at > 25 volts ac or dc on any range except OFF |
|
Frequency | ||
Frequency measurement range |
15 Hz - 400 Hz | |
Frequency measurement accuracy |
±0.5% ± 1 digit | |
Capacitance measurement | ||
Capacitance range | 0.1 nF to 10 μF | |
Accuracy | ± 5.0% ± 2 digits ( 1 nF-10 μF) | |
Cable coefficient | 40n F/ km to 70nF / km | |
Unit of measure | 50nF / km | |
Result storage | ||
Storage capacity | >1000 test results | |
Data download | Bluetooth ® wireless Bluetooth ® Class II |
|
Range | up to 10 m | |
Power supply | ||
Power supply | 6 x 1,5 V cells type IEC LR6 (AA, MN1500, HP7, AM3 R6HP) Alkaline 6 x 1,2 V NiMH rechargeable cells may be used. |
|
Battery life | 3000 insulation tests with duty cycle of 5 sec ON /55 sec OFF @ 500 V into 500 kΩ Charger (Optional): 12-15 V dc (accessory interface) |
|
Dimensions | 228 mm x 108 mm x 63 mm (9.00 in x 4.25 in x 2.32 in) |
|
Weight | 800 g | |
Weight (instrument and case) |
1.75 kg (3.86 lb) | |
Fuse | Use only 2 x 500 mA (FF) 1000 V 32 x 6 mm ceramic fuse of high breaking capacity HBC 30 kA minimum. Glass fuses MUST NOT be fitted. |
|
Safety protection | The instruments meet EN 61010-1 (1995) to 600V phase to earth, Category IV. Refer to safety warnings supplied. |
|
EMC | In accordance with IEC 61326 including amendment No.1 |
|
Temperature co-efficient | <0,1% per °C up to 1 GΩ <0,1% per °C per GΩ above 1 GΩ |
|
Environmental | ||
Operating temperature range and humidity |
-10 to +55 °C 90% RH at 40 °C max. |
|
Storage temperature range | -25 to +70 °C | |
Calibration temperature | +20 °C | |
Maximum altitude | 2000 m | |
IP rating | IP 54 |