Insulation Tester and TRMS Multimeter. Two Powerful Units In One
The Fluke 1577 Insulation Multimeter combines a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
The Fluke 1577 Insulation Multimeter comes with:
- C101 Rugged Utility hard case
- TL224 Suregrip Silicone Test Lead Set
- AC285 Suregrip Alligator CLip Set
- TP165X Remote Test Probe
Whether you work on motors, generators, cables, or switch gear, the Fluke 1577 Insulation Multimeter are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
| Feature |
1587 |
1577 |
| Insulation test voltages 50V, 100V, 250V, 500V, 1000V |
• |
|
| Insulation test voltages 500V, 1000V |
|
• |
| Insulation test: 0.01 MΩ to 2.0 GΩ |
• |
|
| Insulation test: 0.1 MΩ to 600 MΩ |
|
• |
| Auto discharge of capacitive voltage |
• |
• |
| Insulation test smoothing reading |
• |
|
| Frequency |
• |
|
| Capacitance |
• |
|
| Diode test |
• |
|
| Temperature |
• |
|
| Min/Max |
• |
|
| Low pass filter (for work on VSD's) |
• |
|
| AC/DC Voltage |
• |
• |
| DC millivolts |
• |
• |
| AC/DC milliamps |
• |
• |
| Resistance (0.1 Ω to 50 MΩ) |
• |
• |
| Continuity |
• |
• |
| Three-year warranty |
• |
• |
| Remote probe, test leads, alligator clips |
• |
• |
| K-type thermocouple |
• |
|
| Rugged, utility hard case |
• |
• |
| Auto power off to save battery power |
• |
• |
| True-rms |
• |
• |
| Large display with backlight |
• |
• |
| Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection |
• |
• |
| CAT III 1000V, CAT IV 600V measurement category |
• |
• |
| Accepts optional Fluke TPAKTM magnetic hanging system to free your hands for other work |
• |
• |
|
| Specifications |
| Voltage DC |
| Maximum Voltage: |
1000 V |
| Accuracy: |
1577: ±(0.2%+2) |
| |
1587: ±(0.09%+2) |
| Maximum Resolution: |
0.001V |
|
| Voltage AC |
| Maximum Voltage: |
1000 V |
| Accuracy: |
1577: ±(2%+3) |
| |
1587: ±(2%+3) |
| AC Bandwidth: |
1587: 5kHz* |
| |
*with low pass filter; 3db @ 800 Hz |
| Maximum Resolution: |
0.1 mV |
|
| Current DC |
| Maximum Amps: |
400mA |
| Amps Accuracy: |
1577: ±(1.0%+2) |
| |
1587: ±(0.2%+2) |
| Maximum Resolution: |
0.01 mA |
|
| Current AC |
| Maximum Amps: |
400mA |
| Amps Accuracy: |
1577: ±(2.0%+2)* |
| |
1587: ±(1.5%+2)* |
| |
* 1kHz bandwidth |
| Maximum Resolution: |
0.01 mA |
|
| Resistance |
| Maximum Resistance: |
50 MΩ |
| Accuracy: |
1577: ±(1.2%+2) |
| |
1587: ±(0.9%+2) |
| Maximum Resolution: |
0.1Ω |
|
| Capacitance(1587 only) |
| Maximum Capacitance: |
9,999 µF |
| Accuracy: |
±(1.2%+2) |
| Maximum Resolution: |
1 nF |
|
| Frequency (1587 only) |
| Maximum Frequency: |
100 kHz |
| Accuracy: |
±(0.1%+1) |
| Maximum Resolution: |
0.01 Hz |
|
| Temperature Measurement (1587 only) |
| |
-40.0 °C to 537 °C |
| |
-40.0 °F to 998 °F |
| |
excluding probe |
|
| Diode Test (1587 only) |
| Range: |
6 V |
| Resolution: |
1 mV |
| Accuracy: |
±(2 % + 1) |
|
| Insulation Test |
| Minimum Test Current @ 1kΩ/V: |
|
| Test Voltages: |
| 1577: |
500, 1000 V |
| 1587: |
50, 100, 250, 500, 1000 V |
|
| Maximum Resistance per Test Voltage: |
| 50V: |
|
| 100V: |
|
| 250V: |
|
| 500V: |
|
| 1000V: |
1577: 600 MΩ |
| |
1587: 2 GΩ |
|
| Maximum Resolution per Test Voltage: |
| 50V: |
0.01 MΩ |
| 100V: |
0.01 MΩ |
| 250V: |
0.1 MΩ |
| 500V: |
0.1 MΩ |
| 1000V: |
0.1 MΩ |
|
| Accuracy per Test Voltage: |
| 50V: |
±(3 % + 5) |
| 100V: |
±(3 % + 5) |
| 250V: |
±(1.5 % + 5) |
| 500V: |
1577: ±(2.0 % + 5) |
| |
1587: ±(1.5 % + 5) |
| 1000V: |
1577: ±(2.0 % + 5) |
| |
1587: ±(1.5 % + 5) to 600 MΩ, ±(10 % + 3) above 600 MΩ |
|
| Environmental Specifications |
| Operating temperature |
|
| Storage temperature |
|
| Humidity (Without Condensation) |
| |
0% - 95% (10 °C – 30 °C) |
| |
0% - 75% (30 °C – 40 °C) |
| |
0% - 40% (40 °C – 55 °C) |
|
| Operating Altitude |
|
| Safety Specifications |
| Overvoltage category |
| |
Complies with ANSI/ISA 82.02.01 (61010-1) 2004, CAN/CSA-C22.2 NO. 61010-1-04, and IEC/EN 61010-1 2nd Edition for measurement CAT III 1000 V and CAT IV 600 V |
|
| Agency Approvals |
| |
2000 m CAT III 1000 V, CAT IV 600 V; 3000 m CAT II 1000 V, CAT III 600 V |
|
| Mechanical & General Specifications |
| Size |
| |
203 x 100 x 50 mm (with holster) |
|
| Weight |
|
| Warranty |
|
| Battery life Alkaline |
| Meter use: |
1000 hours |
| Insulation test use: |
Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. |
|
| IP Rating |
|
|
|
UK Mainland
|
Order by 2pm for Next Day Delivery*
|
| Under £25.00 |
£4.50 |
| Over £25.00 |
FREE |
|
UK Highlands & Islands
|
Order by 2pm for Next Day Delivery*
|
| Under £80.00 |
£15.00 |
| Over £80.00 |
FREE |