Product Code: MARBZ820-EV
Available In 3-7 Days
The BZ820-EV is the ideal first line tool for checking single phase EV chargers fitted with Type-2 connectors. The unit detects multiple wiring fault conditions and additionally checks the voltage supply level. Correct polarity is indicated by three flashing green LEDs and a continuous audible tone. Fault conditions are clearly indicated by 3 red LEDs and a warning buzzer. Socket polarity and earth wiring faults are identified by a combination of red LEDs. A lookup chart on the tester provides basic fault diagnosis. Further information is available in the product manual.
• Quick & easy EVSE socket testing
• LEDs and buzzer indicate 28 fault conditions
• High/low supply voltage indication
• Type-2 plug connects directly to the EVSE charging point
• Fast and easy testing for the correct wiring of L, N and PE
• The 4 position switch simulates CP mode A, B, C and E
• The Type-2 Connector LEDs indicate charger CP mode and L1 present
• BZ820-EV Socket tester fitted with a type-2 EV charge connector
• Instruction Manual
The BZ820-EV connects to an EVSE charging point using the Type-2 connector. The integral CP mode slider switch allows vehicle states to be simulated: - No vehicle connected (A), vehicle connected but not ready to charge (B) and vehicle connected and ready to charge (C). Mode C is used for testing.
The additional “E” (error) setting simulates failure of the CP signal, which should cause the charger to inhibit charging. LEDs on the integral Type-2 plug show the status of the CP signal and if the voltage supply is present (L1).
Function | BZ820-EV |
Nominal operating voltage | 230V AC RMS |
Operating frequency | 50Hz |
Power consumption | <2.5W |
Power | From mains socket under test |
Standby | After appx 10 minutes |
Voltage low indication | <195V +/- 5% |
Voltage high indication | >270V +/- 5% |
Earth-neutral voltage indication | >30V nominal |
Socket/test lead colours | L,N, PE in 3-wire cable |
Dimensions | 91Lx80Wx38D |
Weight | 120g |
Location | Indoor & outdoor use in dry conditions only |
Altitude | Up to 2000m |
Operating environment | -10deg C to 40deg C max at 85% RH |
Mains supply voltage functions | +/- 10% |
Overvoltage category | CAT III 300V |
Pollution degree | 2 |
Conforms to | Conforms to BS EN 61010-1:2010+A1:2019 Class II reinforced insulation |
Conforms to | BS EN 61326-1 |
UK Mainland | Order by 2pm for Next Day Delivery* |
---|---|
Under £25.00 | £4.50 |
Over £25.00 | FREE |
UK Highlands & Islands | Order by 2pm for Next Day Delivery* |
---|---|
Under £80.00 | £15.00 |
Over £80.00 | FREE |