AMP-210 600A AC TRMS Clamp Meter

  • True-RMS
  • Voltage up to 600 V AC/DC, Current up to 600 A AC, resistance and frequency
  • Low pass filter for variable frequency drives
  • Amp-tip function for precise low current measurements down to the tenth of an Amp
  • Capacitance measurement for start and run motor capacitors
  • Non-contact voltage detection
  • Audible continuity and diode test
  • Data hold, relative zero
  • Large LCD backlit display
  • Accommodates conductors up to 1.18 in (30mm)
  • CAT III 600 V safety rated



*Important Calibration Information:
This instrument comes with a ‘manufacturer's certificate of conformity’. It is important to understand that this does NOT constitute a ‘traceable calibration certificate’. A certificate of conformity merely states that the equipment has been designed and produced to meet the requirements of its intended application.
Where calibration of an instrument is possible, we will offer this as a separately purchasable item and may be selected from the drop-down box above. You will be sent a full traceable calibration certificate produced in our laboratory and applied with your details as required.

  With a full range of AC current, AC/DC voltage, and frequency measurement functions for basic electrical troubleshooting, the AMP-210 clamp meter with its large backlit display is an excellent amp clamp meter choice. Rated CAT III 600 V, the AMP-210 clamp meter offers True-RMS sensing, fast response processor, non-contact voltage detection, capacitance, resistance and continuity measurements to enhance efficiency and safety in today’s complex electrical environments.

Included Accessories: Test Leads, (2) AAA Batteries (installed), User Manual, Carrying Case

The Amp-Tip function allows for precise measurement of current down to the tenth of an Amp, enabling accurate current measurement of both large and small diameter wires. A low pass filter allows measurement of current and voltage on variable frequency drives (motors with speed controlled by frequency).

 

  • Measures AC Current to 600 A and AC/DC Voltage to 600 V
  • Features True-RMS sensing for accurate voltage measurements in noisy electrical environments
  • Amp-Tip delivers precise low AC current measurements – 0 to 60 A
  • Includes a low pass filter to accurately measure voltage and current on variable frequency drives
  • Capacitance measurement, continuity beeper and diode test
  • Provides resistance and continuity measurement capabilities to verify the quality of electrical connections and the proper operation of motor and transformer coils
  • Offers data hold and relative zero for quick analysis
  • Maximizes battery life with auto power off and low battery indicator
  • Backlit display for easy measurement viewing in bright and dim environments
  • Accommodates conductors up to 1.18 in (30mm)
  • Includes test leads, batteries (installed), carrying case, and user manual
  • CAT III 600 V safety rated

 

FEATURE AMP-210 AMP-220 AMP-310 AMP-320 AMP-330
AC voltage (True-rms) Range: 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.0% + 5LSD (50 to 60 Hz) ±0.8% + 5LSD (50 to 60 Hz)
DC voltage Range: 0 to 600.0 V
Accuracy: ±1.0% + 5LSD
AC+DC voltage Range: 0 to 600.0 V 0 to 600.0 V 0 to 1000.0 V
Accuracy: ±1.2% + 7LSD (50 to 60 Hz) ±1.2% + 7LSD (50 to 60 Hz) ±1.0% + 7LSD (50 to 60 Hz) 
±1.8% + 7LSD (DC 40 to 200 Hz) 
±1.2% + 7LSD 200 to 400 Hz)
AC current Range: 0 to 600.0 A
Accuracy: ±1.8% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (100 to 400 Hz)
DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.0% + 5LSD (DC 50 to 100 Hz) ±2.0% + 5LSD (DC 50 to 100 Hz) ±1.8% + 5LSD (DC 50 to 100 Hz)
AC+DC current Range: 0 to 600.0 A 0 to 600.0 A 0 to 1000.0 A
Accuracy: ±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (DC 50 to 100 Hz) 
±2.7% + 7LSD (100 to 400 Hz)
±2.2% + 7LSD (40 to 100 Hz) 
±2.5% + 7LSD (100 to 400 Hz)
Precise low current AC Range: 0 to 60.00 A
Accuracy: ±1.5% + 5LSD (50 to 60 Hz) ±1.5% + 5LSD (50 to 60 Hz) 
±2.0% + 5LSD (0.00 to 20.00 A, 100 to 400 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 40 to 100 Hz) 
±3.0% + 5LSD (>20.00 to 60.00 A, 100 to 100 Hz)
Precise low current DC Range: 0 to 60.0 A 0 to 60.0 A 0 to 60.00 A
Accuracy: ±2.0% + 5LSD ±2.0% + 5LSD ±1.5% + 5LSD (0.00 to 20.00 A) 
±3.0% + 5LSD (>20.00 to 60.00 A)
Micro amps Range: 0 to 2000 µA
Accuracy: ±1.0% + 5LSD
Frequency Range: 5.00 to 999.9 Hz
Accuracy: ±1.0% + 5LSD (600 V range)
Range: 50.0 to 400.0 Hz
Accuracy: ±2.0% + 4LSD (600 A range)
Resistance Range: 0.0 to 60.00 kΩ
Accuracy: ±1.0% + 5LSD
Capacitance Range: 0.0 to 2500 µF
Accuracy: ±2.0% + 4LSD
Continuity beeper ON ≤ 10 Ω
Off > 250 Ω
Temperature* 
(Type K thermocouple)
  -40.0 to 752 °F
-40.0 to 400 °C
  ±1.0% + 3.0 °F (-40.0 to 14.0 °F) 
±1.0% + 1.5 °F (>40.0 to 99.9 °F) 
±1.0% + 2.0 °F (100 to 752 °F) 
±1.0% + 1.5 °C (-40.0 to 10.0 °C) 
±1.0% + 0.8 °C (>-10.0 to 99.9 °C) 
±1.0% + 1.0 °C (100 to 400 °C) 
Non-contact voltage 10 V to 1000 V AC (50 to 60 Hz)
Phase rotation indication   Rotation-R for main supply 
Rotation-M for motors
Diode test  
Jaw opening   1.18 in (30 mm) 1.37 in (35 mm) 1.18 in (30 mm) 1.37 in (35 mm) 2.0 in (51 mm)
Safty rating   CAT III 600 V CAT IV 600V 
CAT III 1000 V
Special Features
In-rush current  
Peak hold (Crest)  
Relative zero  
Max/Min/Avg  
Data hold  
Backlight  
Auto power off  
Work light  

*Error does not include Type-K thermocouple errors