To avoid dangerous levels of CO, it is important to maintain all combustion appliances in good working order: charcoal heaters, gas heaters, wood stoves, water heaters, gas stoves, and open chimneys; schedule chimney-sweeping and flare conduit cleaning at least once a year. One must ensure that there is adequate ventilation in rooms containing combustion installations (kitchen, garage, bathroom) and especially avoid blocking or crushing ventilation apertures.
XREF_BRAND | Chauvin Arnoux |
---|---|
XREF_MANU | #N/A |
De 0 to 1 ppm | normal level of CO in the air |
9 ppm | maximum level in a room with no harm to health |
50 ppm | maximum level bearable for continuous exposure during 8 hours |
200 ppm | mild headache, nausea, dizziness |
400 ppm | serious headache, life threatening after 3 hours |
800 ppm | death after 2 hours |
1,600 ppm | nausea in 20 minutes, death after 1 hour |
12,800 ppm | death within 1 to 3 minutes |
Chauvin Arnoux CA895 Carbon Monoxide Detector | ||
Measurement range | 0 to 1000 ppm | |
Accuracy | ± 5 ppm ± 5 % of the reading | |
Measurement modes | Normal | for detecting the CO source |
Average | for an accurate measurement |